Same-day 2-hour delivery in Bali30-day money-back guaranteeCold-packed, sealed and trackedLab report with every batchSame-day 2-hour delivery in Bali30-day money-back guaranteeCold-packed, sealed and trackedLab report with every batchSame-day 2-hour delivery in Bali30-day money-back guaranteeCold-packed, sealed and trackedLab report with every batchSame-day 2-hour delivery in Bali30-day money-back guaranteeCold-packed, sealed and trackedLab report with every batch
Genix.

Published lot document

GHK-Cu · ID-GHK-100-830472

This page publishes the original PDF supplied for lot 830472. 99.10% HPLC area, lot 830472, 100 mg. HPLC area purity is not content, identity, sterility, safety or efficacy.

Compound / composition
GHK-Cu, 100 mg lyophilized solid
Lot number
830472
Report ID
ID-GHK-100-830472
Tested size
100 mg
Issuing laboratory (as printed)
MZ Biolabs, LLC
Analysis date
June 9, 2026
Report date
June 10, 2026
Current shipping lot
Not confirmed. Do not assume this is the lot now being shipped.
Catalog SKU match
ghk-cu · 100mg
Verification
A verification address is printed on the document. It has not been independently confirmed here as an unaffiliated laboratory portal.

Methods and results

Values below are copied from page 1 of the original PDF, with units as printed.

AnalyteMethodResultSpecification
AppearanceVisualBlue lyophilized solidBlue lyophilized solid
IdentityLC-MS401.9 amuObserved mass conforms to structure
Purity (HPLC area)HPLC-UV (220 nm)99.10 %Minimum 98.00% by chromatogram area
Peptide / compound contentNitrogen content elemental analysis98.70 %Report actual content percentage
Copper contentICP-OES15.7 % w/w15.0 – 16.5% w/w
Lead (Pb)ICP-MS (USP <232>/<233>)< 0.20 ppm≤ 10 ppm
Arsenic (As)ICP-MS (USP <232>/<233>)< 0.05 ppm≤ 1.5 ppm
Cadmium (Cd)ICP-MS (USP <232>/<233>)< 0.05 ppm≤ 0.50 ppm
Mercury (Hg)ICP-MS (USP <232>/<233>)< 0.10 ppm≤ 1.5 ppm

Limitations

  • HPLC area purity is not peptide content, identity, sterility, safety or efficacy.
  • Results apply only to the printed lot and the tested fill size.
  • The document states laboratory research use only, not for human use.
  • Genix Labs publishes this explanatory page. The laboratory name is recorded as printed on the document.
  • A verification address is printed on the document. This website has not independently confirmed that address as an unaffiliated laboratory portal.

Original PDF

The preview is supplementary. Use the download button if the embedded viewer is unavailable.

Direct original PDF

PDF preview is not available in this browser. Download the original PDF.